EDGCNTA_EN=DISABLED, ONESHOTA=FREE_RUNNING, EDGA0=DISABLED, ARMA=DISABLED, EDGA1=DISABLED, INP_SELA=PWM_A
Capture Control A Register
ARMA | Arm A 0 (DISABLED): Input capture operation is disabled. 1 (ENABLED): Input capture operation as specified by CAPTCTRLA[EDGAx] is enabled. |
ONESHOTA | One Shot Mode A 0 (FREE_RUNNING): Free Running 1 (ONE_SHOT): One Shot |
EDGA0 | Edge A 0 0 (DISABLED): Disabled 1 (FALLING_EDGE): Capture falling edges 2 (RISING_EDGE): Capture rising edges 3 (ANY_EDGE): Capture any edge |
EDGA1 | Edge A 1 0 (DISABLED): Disabled 1 (FALLING_EDGE): Capture falling edges 2 (RISING_EDGE): Capture rising edges 3 (ANY_EDGE): Capture any edge |
INP_SELA | Input Select A 0 (PWM_A): Raw PWM_A input signal selected as source. 1 (EDGE_COUNTER): Edge Counter |
EDGCNTA_EN | Edge Counter A Enable 0 (DISABLED): Edge counter disabled and held in reset 1 (ENABLED): Edge counter enabled |
CFAWM | Capture A FIFOs Water Mark |
CA0CNT | Capture A0 FIFO Word Count |
CA1CNT | Capture A1 FIFO Word Count |